The HS2048 is a compact miniature spectrometer with a configurable spectral range.
It features high resolution (up to 0.07 nm), low stray light (~0.1%), and excellent thermal stability (wavelength drift ~0.1 pixel/°C). It is suitable for laser measurement, plasma emission spectroscopy, color analysis, absorbance measurement, and Raman spectroscopy, making it a high-performance, cost-effective industrial-grade fiber optic spectrometer.
-
Features
- Low stray light: ~0.1%
- High resolution: up to 0.07 nm
- Low-temperature drift design, wavelength temperature drift ~0.1pixel/℃
- Compatible with Oceanhood multi-core bundle fibers (insertion consistency ≤7%)
- Strong UV spectral response
- High performance AD quantization sampling circuit, CCD quantization background noise ≤30RMS (at minimum integration time);
- Supports multiple communication interfaces: USB, RS232, and 24PIN interactive interface.
- Configure proprietary DAC and ADC, can achieve supporting light source enable, intensity control and power feedback.
-
Specification
| Optical parameters | |
| Optical fiber interface | Key-SMA905 |
| Number of pixels | 2048pixels |
| Stray light | ~0.1% |
| Wavelength shift with temperature | 0.1pixel/℃ |
| Consistency of optical fiber insertion and removal | ≤7% |
| Function parameters | |
| AD sampling | 16bit |
| Data interface | USB2.0、RS232 |
| Extended function interface | 24PIN |
| Acquisition mode | Single, continuous, software trigger, synchronous external trigger, asynchronous reset external trigger |
| Detector integration time | 60μs-65S |
| Accuracy of external trigger delay | 10ns |
| CCD read noise1 | ≤30 |
| CCD dynamic range2 | 3000:1 |
| Signal-to-noise ratio | 380:1 |
| Response linearity3 | ≥98% |
| Others | |
| Weight | ≈260g |
| Dimension | 98×80×24 mm |
| Operating temperature | 0℃~40℃ |
| Working humidity | 20%-85% |
|
1.CCD readout noise: the RMS value of the CCD readout noise at the minimum integration time.
2.CCD dynamic range: calculated under minimum integration time as (saturation value − dark noise baseline) / standard deviation of CCD readout noise, evaluated according to Oceanhood Opto-Electronics standards.
3.Response linearity: The response nonlinearity is measured before calibration. |
|
-
Products
| Model | Spectral Range | Spectral resolution | |||||
| Start | End |
10µm
|
25µm
|
50µm | 100µm |
200µm
|
|
| HS2048-200-800 | 200 | 800 | 0.90 | 1.00 | 1.40 | 2.40 | 3.50 |
| HS2048-350-940 | 350 | 940 | 0.80 | 1.00 | 1.50 | 2.40 | 3.60 |
| HS2048-200-1100 | 200 | 1100 | 1.00 | 1.80 | - | 3.00 | 4.20 |
| HS2048-350-1050 | 350 | 1050 | 0.90 | 1.00 | 1.60 | 2.80 | 4.00 |
► Spectral range and parameters can be customized.
► Resolution values may vary by 120% from nominal.
-
Dimensional drawing

-
Testing results
Dark noise (Integral time:10ms)
Dark noise VS integration time
Signal-to-noise ratio
Dynamic range
Standard light source (200-800 nm)
Deuterium tungsten light source (200-800 nm)
Photoluminescence (PL) measurement results