CS200 is a miniature fiber optic spectrometer based on symmetrical CT optical path design. It has a compact size and the spectral range can be configured as requested. It features high resolution (the best up to 0.07nm) and low temperature drift (~0.1pixel/℃), and is suitable for laser measurement, plasma emission spectrum measurement, color measurement, absorbance measurement and Raman measurement and other industrial field measurement. CS200 is an industrial fiber optic spectrometer with high performance.
-
Features
- Based on the traditional CT optical path design, excellent stray light absorption structure and high-performance imported plane reflection grating, the light path stray light ~0.2%;
- High resolution, the best up to 0.07nm;
- Low-temperature drift design, wavelength temperature drift ~0.1pixel/℃;
- Key-SMA905 design, suitable for kelp pin multi-core dense cluster fiber, fiber insertion strength consistency ≤7%;
- Equipped with UV-enhanced linear array CMOS detector, UV spectral response is strong;
- High performance AD quantization sampling circuit, CCD quantization background noise ≤30RMS (100ms integration time);
- Configure USB, serial communication interfaces, configure 24PIN interactive interface, configure proprietary DAC and ADC, can achieve supporting light source enable, intensity control and power feedback.
-
Specification
Optical parameters | |
Optical fiber interface | Key-SMA905 |
Slit | 10μm、20μm、25μm、50μm、100μm、200μm (customizable) |
Detector | CMOS detector |
Number of pixels | 2048pixels |
Stray light | ~0.2% |
Wavelength shift with temperature | ~0.1pixel/℃ |
Consistency of optical fiber insertion and removal | ≤7% |
Function parameters | |
AD sampling | 16bit |
Data interface | USB2.0、RS232 |
Extended function interface | 24PIN |
Acquisition mode | Single, continuous, software trigger, synchronous external trigger, asynchronous reset external trigger |
Detector integration time | 50μs-65S |
CCD read noise1 | ≤30 |
CCD dynamic range2 | 1300:1 |
Signal-to-noise ratio | 300:1 |
Response linearity3 | ≥98% |
Others | |
Weight | ≈190g |
Dimension | 75×63.5×35 mm |
Operating temperature | 0℃~40℃ |
Working humidity | 20%-85% |
1. CCD readout noise: integration time 10ms, CCD readout noise root mean square; 2. CCD dynamic range: the dynamic range is the saturation value of 2ms integration time/the root mean square of CCD readout noise, the evaluation method refers to the standard of enterprise; 3. Response linearity: The response nonlinearity is before calibration.
|
-
Products
Model | Number of pixels | Spectral Range | Frame rate | Spectral resolution(nm) | |||
Pixels
|
Start | End | frame/s |
10um
|
25um
|
50um
|
|
CS200-200-850
|
2048
|
200
|
850
|
- |
-
|
1.5 |
-
|
CS200-350-1020
|
2048
|
350
|
1020 | - |
-
|
1.5
|
-
|
-
Dimensional Drawing
-
Testing Results
Signal-to-noise ratio
Standard light source (200-800nm)