PRODUCTS

Fiber Optic Spectrometers General Purpose Spectrometers

DETAIL

The TEC2000 is a cooled, back-illuminated miniature fiber optic spectrometer with a compact design and configurable spectral range. It features high resolution (up to 0.07nm), low stray light (~0.5%), and excellent spectral stability and reproducibility, suitable for long-term industrial monitoring. Applications include laser measurement, plasma emission spectroscopy, color analysis, absorbance testing, and Raman spectroscopy.

  • Features

  • High resolution, the best up to 0.07nm;
  • Equipped with TE-cooled CCD detector, the cooling temperature can be selected according to the configuration of 10 or -5;
  • With low reading dark noise and good stability;
  • Key-SMA905 design, suitable for Oceanhood multi-core dense cluster fiber, fiber insertion strength consistency 7%;
  • Designed for long-term stable monitoring in industrial and research applications;
  • CCD background noise ≤10 RMS (minimum integration time);
  • Multiple interfaces including USB, RS232, 24-pin interactive interface;
  • Built-in DAC and ADC for light source control, intensity adjustment, and power feedback.

 
  • Specification

Optical parameters
Optical fiber interface Key-SMA905
Number of pixels1 2048 pixels
Stray light ~0.5%
Consistency of optical fiber insertion and removal 7%
Function parameters
AD sampling 16bit
Data interface USB2.0、RS232
Extended function interface 24PIN
Acquisition mode Single, continuous, software trigger, synchronous external trigger, asynchronous reset external trigger
Detector integration time 8ms-30s(Max)
CCD read noise2 ≤10
CCD dynamic range3 8000:1
CCD dynamic range (full signal)4 15000:1
Signal-to-noise ratio 800:1
Response linearity5 98%
Others
Weight ≈1.12kg
Dimension 182×109×56mm
Operating temperature 0℃~40℃
Working humidity 20%-85%
1.CCD Pixel Channels: 2048×1 pixels
2.CCD Readout Noise: RMS value at minimum integration time
3.CCD Dynamic Range: Calculated as (saturation value − dark noise baseline) / standard deviation of CCD readout noise, evaluated per Oceanhood standards
4.Full-Signal Dynamic Range: Based on CCD manufacturer or industry reference specifications
5.Response Linearity: Measured before calibration
 
 
 
  • Products

    Model

    Cooling

    temperature
    Spectral Range Spectral resolution
    °C
    Start End
    25µm
    TEC2000-535-630 -5/10 535 630 0.30
    TEC2000-795-1040 -5/10 795 1040 0.45
    TEC2000-200-1000 -5/10 200 1000 2.50
 
 

  • Dimensional drawing

 
  • Testing results

Dark noise (Integration time:10ms)

 
Dark noise VS Integration time


Signal-to-noise ratio 
(Integration time:10ms, active)


 
Dynamic range



Standard light source (200-1000nm)


 
Deuterium tungsten light source (200-1000nm)