General Purpose Spectrometers

High Sensitivity Spectrometer - XS11639

XS11639 is a basic optical fiber spectrometer with a cross CT structure design. It has a compact size and the spectral range can be configured between 190-1100nm.
DETAIL

XS11639 is a basic optical fiber spectrometer with a cross CT structure design. It has a compact size and the spectral range can be configured between 190-1100nm. With special lens fixing process and photoelectric separation structure, it has good temperature stability and reliability. Furthermore, we chose the UV-enhanced CMOS detector which can optimize the UV response.

XS11639 is the valuable spectrometer which can be used in color measurement, radiation measurement, absorption measurement, fluorescence spectrum, Raman spectrum and other measurement scenarios.



  • Features

  • Configurable spectral range: 190-1100nm;
  • Key-SMA905 design, suitable for kelp pin multi-core dense cluster fiber, fiber insertion strength consistency 7%;
  • Equipped with UV-enhanced linear array 2048 pixels CMOS detector, UV spectral response is strong;
  • High performance AD quantization sampling circuit, CCD quantization background noise 30RMS (100ms integration time);
  • Configure USB, serial communication interfaces, configure 24PIN interactive interface, configure proprietary DAC and ADC, can achieve supporting light source enable, intensity control and power feedback.
 
  • Specification

Optical parameters
Optical fiber interface Key-SMA905
Slit 10μm、20μm、25μm、50μm、100μm、200μm
(customizable)
Detector CMOS detector
Number of pixels 2048pixels
Stray light <1%
Wavelength shift with temperature ~0.3pixel/
Consistency of optical fiber insertion and removal 7%
Function parameters
AD sampling 16bit
Data interface USB2.0、RS232
Extended function interface 24PIN
Acquisition mode Single, continuous, software trigger, synchronous external trigger, asynchronous reset external trigger
Detector integration time 50μs-65S
CCD read noise1 30
CCD dynamic range2 3300:1
Signal-to-noise ratio 380:1
Response linearity3 98%
Others
Weight ≈190g
Dimension 75×63.5×35 mm
Operating temperature 0℃~40℃
Working humidity 20%-85%

1. CCD readout noise: integration time 10ms, CCD readout noise root mean square;

2. CCD dynamic range: the dynamic range is the saturation value of 2ms integration time/the root mean square of CCD readout noise, the evaluation method refers to the standard of enterprise;

3. Response linearity: The response nonlinearity is before calibration.
 

 
  • Products
Model Number of pixels Spectral Range Frame rate Spectral resolution
Pixels
Start End frame/s
10um
25um
50um
XS11639-200-1000 2048 200 1000 - - 1.80 -
XS11639-190-920 2048 190 920 - 0.8 1.50 -
XS11639-350-1050 2048 350 1050 - - 1.30 2
XS11639-190-540 2048 190 540 - - 0.70 -
XS11639-790-1060 2048 790 1060 - 0.4 0.6 0.9
XS11639-190-410 2048 190 410 - - 0.45 0.7
XS11639-530-700 2048 530 700 - - 0.35 -

 


  • Dimensional drawing



 
  • Testing results

Dark noise (Integral time:10ms)
 

 
Dark noise VS Integral time
 


Signal-to-noise ratio


 
Dynamic range



Standard light source (200-800nm)


 