671nm Lasers

Single Longitudinal Mode 671nm Laser- MSL-U-671

The single longitudinal mode 671nm laser is made features of ultra compact, long lifetime, low cost and easy operating.
DETAIL
It can be used in DNA sequencing, flow cytometry, cell sorting, optical instrument, spectrum analysis, interference, measurement, holography, physics experiment, etc.


 
  • Dimensional Drawing
    Laser Head Power Supply


    142.5 (L)×60(W) ×50(H) mm3, 1.0 kg


    75(L) ×145(W) ×104(H) mm3, 2.3 kg
 
  • Specifications
Model MSL-U-671
Wavelength (nm) 671±1
Operating mode CW
Output power (mW) 1-400
Power stability (rms, over 4 hours) <1%, <2%, <3%
Transverse mode TEM00
Longitudinal mode Single
Spectral line width (nm) <0.00001
Noise of amplitude (rms, 1Hz~20MHz) <0.5%, <1%
M2 factor <1.2
Beam diameter at the aperture (1/e2, mm) <1.0
Beam divergence (mrad) <1.5
Polarization Ratio >100:1, (Horizontal or Vertical Optional)
Warm-up time (minutes) <5
Pointing stability after warm-up (mrad) <0.05
Coherent length (m) >50
Beam height from base plate (mm) 27.4
Laser head consumption(W) 15 (typical), <25 (40)
Max. Laser Head Base plate Temp (°C) 50
Operating Temperature (°C) 10-40
Power supply (90-264VAC) PSU-H-FDA
Expected lifetime (hours) 10000
Warranty 1 year
Note: The laser head needs to be used on a heat sink with good heat dissipation.