General Purpose Spectrometers

Fiber Optic Spectrometer - Area2000

Area2000 is a latest miniature fiber optic spectrometer of Oceanhood Taiwan. It has a compact size and the spectral range can be configured as requested.
DETAIL

Area2000 is a latest miniature fiber optic spectrometer of Oceanhood Taiwan. It has a compact size and the spectral range can be configured as requested. It features high resolution (the best up to 0.07nm) and low temperature drift(~0.1pixel/). It is a high-performance fiber optic spectrometer which is suitable for laser measurement, plasma emission spectrum measurement, color measurement, absorbance measurement and Raman measurement and other industrial field measurement.


 

  • Features

  • Light path stray light ~2‰ ;
  • High resolution, the best up to 0.07nm ;
  • Low-temperature drift design, wavelength temperature drift ~0.1pixel/ ;
  • Key-SMA905 design, suitable for kelp pin multi-core dense cluster fiber, fiber insertion strength consistency 7% ;
  • Good sensitivity in the UV-VIS range ;
  • High performance AD quantization sampling circuit, CCD quantization background noise 30RMS (100ms integration time) ;
  • Configure USB, serial communication interfaces, configure 24PIN interactive interface, configure proprietary DAC and ADC, can achieve supporting light source enable, intensity control and power feedback.
 

  • Specification

Optical parameters
Optical fiber interface Key-SMA905
Number of pixels 2048×64 pixels
Stray light ~2‰
Wavelength shift with temperature 0.1pixel/
Consistency of optical fiber insertion and removal 7%
Function parameters
AD sampling 16bit
Data interface USB2.0、RS232
Extended function interface 24PIN
Acquisition mode Single, continuous, software trigger, synchronous external trigger, asynchronous reset external trigger
Detector integration time 50μs-65S
Accuracy of external trigger delay 5ns
CCD read noise1 30
CCD dynamic range2 1300:1
Signal-to-noise ratio 400:1
Response linearity3 98%
Others
Weight ≈300g
Dimension 100×85×28.5 mm
Operating temperature 0℃~40℃
Working humidity 20%-85%

1. CCD readout noise: integration time 10ms, CCD readout noise root mean square;

2. CCD dynamic range: the dynamic range is the saturation value of 2ms integration time/the root mean square of CCD readout noise, the evaluation method refers to the standard of enterprise;

3. Response linearity: The response nonlinearity is before calibration.
 

 
  • Products
Model Number of pixels Spectral Range Frame rate Spectral resolution
Pixels
Start End frame/s
10um
25um
50um
Area2000-300-1000
2048×64
300
1000
200
-
1.00
-
Area2000-200-800
2048×64
200
800
200
-
0.80
-
Area2000-350-950
2048×64
350
950
200
-
0.80
-
Area2000-380-780
2048×64
380
780
200
-
0.70
-
Area2000-230-450
2048×64
230
450
200
0.32
-
-
Area2000-450-700
2048×64
450
700
200
0.32
-
-
Area2000-200-380
2048×64
200
380
200
0.13
0.30
0.45
Area2000-535-660
2048×64
535
660
200
0.12
0.25
-




 

  • Dimensional drawing




 
  • Testing results

Dark noise (Integral time:10ms)


Dark noise VS integration time


Signal-to-noise ratio


Dynamic range


Standard light source (200-800 nm)


Deuterium tungsten light source (200-800 nm)